Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
Add filters








Year range
1.
Chinese Journal of Medical Instrumentation ; (6): 400-404, 2018.
Article in Chinese | WPRIM | ID: wpr-775545

ABSTRACT

In aging society the development of non-invasive continuously blood pressure monitors which are suitable for homes, communities and nursing homes has a wide range of applications. This paper proposes a non-invasive continuously blood pressure monitoring based on wearable device which uses MSP430F5529 as the central processor. The design is divided into signal acquisition module, central control module, display module, power supply module and host computer module. The experimental results showed that DBP (375/390, 96.15%) and SBP estimation values (377/390, 96.67%) are in 95% confidence interval, which means our design passes Bland-Altman test with high accuracy and stability.


Subject(s)
Blood Pressure , Blood Pressure Determination , Blood Pressure Monitors , Electric Power Supplies , Wearable Electronic Devices
2.
Chinese Medical Equipment Journal ; (6): 6-11,15, 2017.
Article in Chinese | WPRIM | ID: wpr-662183

ABSTRACT

Objective To develop an ECG monitoring and management system based on the smartphone platform to transmit ECG data to the doctor in daily life or working environment.Methods The system was composed of an ECG signal acquisition device and a smartphone App.The ECG signal acquisition device used MSP430F149 microcontroller as the core unit,which executed ECG signal extraction by adopting right leg drive,active filters,dual instrumentation amplifier and moving average algorithm,applied differential threshold method to accurately detecting R wave,calculated heart rate and then sent ECG data to the smartphone through Bluetooth 4.0 module.The smartphone App was developed based on cross-platform mobile development framework Cordova,and used Cordova plugins,JavaScript,HTML5 and CSS to receive the data from the acquisition device,draw and store ECG,show heart rate and remind abnormalities in heart rate as well as to transmit ECG data to the doctor through the mobile medicine App and social App.Then the doctor provided advices on prevention,treatment and etc after analyzing the received data.Results Compared with the ECG machine,the system had the relative errors of heart rate,P duration,QRS duration and QT duration being 2.7%,4.5%,4.3% and 3.3% respectively.All the above four parameters having significant correlations,and the correlation parameters were 0.955,0.948,0.91 and 0.834 respectively (P<0.05).The system had 8-h endurance in case of being fully charged.Concluslon The system gains advantages in power consumption,accuracy,noise,cost,volume,weight,safety,reliability as well as easy operation and maintenance,and facilitates the ECG conditions to be mastered timely by the doctor.

3.
Chinese Medical Equipment Journal ; (6): 6-11,15, 2017.
Article in Chinese | WPRIM | ID: wpr-659537

ABSTRACT

Objective To develop an ECG monitoring and management system based on the smartphone platform to transmit ECG data to the doctor in daily life or working environment.Methods The system was composed of an ECG signal acquisition device and a smartphone App.The ECG signal acquisition device used MSP430F149 microcontroller as the core unit,which executed ECG signal extraction by adopting right leg drive,active filters,dual instrumentation amplifier and moving average algorithm,applied differential threshold method to accurately detecting R wave,calculated heart rate and then sent ECG data to the smartphone through Bluetooth 4.0 module.The smartphone App was developed based on cross-platform mobile development framework Cordova,and used Cordova plugins,JavaScript,HTML5 and CSS to receive the data from the acquisition device,draw and store ECG,show heart rate and remind abnormalities in heart rate as well as to transmit ECG data to the doctor through the mobile medicine App and social App.Then the doctor provided advices on prevention,treatment and etc after analyzing the received data.Results Compared with the ECG machine,the system had the relative errors of heart rate,P duration,QRS duration and QT duration being 2.7%,4.5%,4.3% and 3.3% respectively.All the above four parameters having significant correlations,and the correlation parameters were 0.955,0.948,0.91 and 0.834 respectively (P<0.05).The system had 8-h endurance in case of being fully charged.Concluslon The system gains advantages in power consumption,accuracy,noise,cost,volume,weight,safety,reliability as well as easy operation and maintenance,and facilitates the ECG conditions to be mastered timely by the doctor.

4.
Chinese Medical Equipment Journal ; (6): 6-8,46, 2015.
Article in Chinese | WPRIM | ID: wpr-602046

ABSTRACT

Objective To design a high performance and low power consumption ECG signal acquisition system which can meet the demand for long time monitoring of the physiological status of patients.Methods The prototype system utilized low power ECG analog front end ADAS1000 and MSP430F5529 microcontroller to achieve configuration of AFE and back-reading of ECG data by SPI bus. Results This system implemented 24-hour dynamic ECG monitoring of patients in active state, and the data acquired were accurate and reliable.Conclusion The system realizes PCB integration, low power consumption, and can be used for battery powered portable application such as wearable devices.

5.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-595494

ABSTRACT

Objective To design a new kind of wireless monitoring thermometer which can help the doctor to monitor the patient's temperature without touching them. Methods The system is based on a new kind of single chip MSP430F413,the thermistor was used in temperature detect part; the single chip's comparator A and timer A was used in A/D converter part to realize slop A/D; the NRF2401 chip was used in wireless transmission part; the system is connected with PC in the way of serial communications. Results The thermometer can work in -40 to 85 ℃ when the temperature is near animal heat,the thermometer is most accurate which precision is 0.1 ℃. Conclusion The system can measure the patient's temperature accurately,at the same time,the temperature data is sent to the receiving end in the way of wireless communication,and then data is sent to PC,which PC can record the temperature curve data and help the doctors to diagnose.

6.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-589409

ABSTRACT

For the purpose of monitoring real-time information of infant bed-wetting,this paper presents a medical digital wireless monitoring system with low-cost and high-performance. Its hardware is based on micro-controller,MSP430 ultra low-power and RF IC,nRF905 single wireless chip. With this wireless system,real-time information of infant bed-wetting can be monitored,and thus the nurses' work load can be reduced.

7.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-583359

ABSTRACT

The basic principle,characters and applications of I 2 C bus protocol are introduced in this paper.Its application to implantable e lectrical stimulator is also described based on MAX5630,a DAC chip produced by M AXIM Corporation.

8.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-596366

ABSTRACT

Objective To design and develop a kind of SpO2 detection and analysis system based on LabVIEW. Methods Pulse signal process and SpO2 calculation were achieved by designing a control system based on TI Company's MSP430FG439 MCU and using the digital signal process and graphic controls of the LabVIEW software. The design project and the realization way were given out by discussing the software of LabVIEW. Results The system could acquire, display and process pulse signal and calculate SpO2. Conclusion The system carries out a new way to design medical monitor equipment. Furthermore, it provides a shortcut for special analysis of the SpO2 and pulse signal in clinic.

9.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-593313

ABSTRACT

Objective To design an ECG Holter system based on wireless data communication. Methods The system utilized low power microcontroller MSP430F149 to achieve wireless data transmission by module MC35I. ECG data which stored temporarily in SD card were transmitted in the form of SMS through wireless networks. The received messages were converted into intact files of ECG by data integration. Results It realizes ECG playback, analysis and can send messages automatically to inform relatives and doctors. Conclusion The preliminary clinical application indicates that the Holter has stable performance and strong anti-interference ability, and especially suitable for critical patient care.

10.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-587924

ABSTRACT

An audio communication system in field medicine based on wireless transmission is introduced.It mainly comprises MSP430 ultra low-power and 16-bit microcontroller of Texas Instruments and wireless audio streamer nRF24Z1 of Nordic VLSI in Norway.The system realizes the call-and-talk communication between doctors and patients conveniently in one-to-many way in good audio quality and flexible mobility,so that doctors can be timely informed the state of an illness by using it.

11.
Chinese Medical Equipment Journal ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-584856

ABSTRACT

A dynamic electrocardiogram record system based on MSP430 SCM is developed in this paper. MSP430 SCM has ultra-low power consumption and a high integration level. The gathered ECG data are stored on a CF card. With low power consumption and being portable, the system is especially suitable for the occasion with the battery as power supply.

12.
Chinese Medical Equipment Journal ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-583744

ABSTRACT

As a substitute of the traditional auscultoscope, the midget ultrolow power consumption ECG auscultoscope combines the traditional one with the electrocardiograph, which is easy to operate and carry.

13.
Chinese Medical Equipment Journal ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-589198

ABSTRACT

This paper discusses the design of a special digital manometer for air-pocket in manual air-way. Integrated silicon pressure sensor MPX5010 with high precision and sensitivity is adopted in the device. It can not only measure and display air pressure of air-pocket,but also give the alarm for excessive pressure,thus providing a timely and convenient way for clinician to control air-pocket pressure,which ensures the safety and precision for clinic.

14.
Chinese Medical Equipment Journal ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-589195

ABSTRACT

Objective In order to carry out the research of the non-invasive core temperature measurement,the paper designs a portable sixteen channels temperature measurement system. Method Using MCU MSP430F149,this paper applies the technology of analog signal acquisition and digital signal process to establish a multi-channel temperature system. Result The system can store and send the temperature signals through wire and wireless communication mode. Conclusion The system is stable and reliable,and the precision of the system satisfies the clinical demand.

15.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-583661

ABSTRACT

Healthcare at home is accepted little by little with the development of medical service in the community. This paper introduces the design method of mobile ECG monitoring system terminal for healthcare at home. The adoption of active electrode and digital trap contributes to the elimination of the external interference. Low-power-consumption MSP430 micro-controller applied, the realtime acquisition, procession and transmission to PDA of ECG are performed.

16.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-596968

ABSTRACT

Objective To develop a continuous temperature monitoring device for the infant,with the function of high temperature alarm.Methods The comparator and counter of MSP430F435 SCM and some peripheral circuits was applied to high-precision temperature measurement,and then the data were stored in the flash of MSP430F435 SCM.Results The device could display realtime temperature and alarm in case of abnormal temperature,which made continuous monitoring of 30 days realized.Conclusion The device,being low-cost,low-power-consumption and low-volume,is worth popularizing for dynamic monitoring of infant temperature.

17.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-594377

ABSTRACT

Objective To develop a kind of mobile Bluetooth temperature sensor with removable measurement and wireless transmission.Methods The device was designed with technology of high precision sensor and newly developed Bluetooth base on MCU MSP430 as control unit which could apply in real time measurement,data storage,transmission and emergency alarm.Results The problem that at the scene of many cables in clinical care of the devise was resolved.Any devices with Bluetooth sensor can receive temperature data.Conclusion The traditional work mode is changed by the Bluetooth device and reduces the workload of nursing staff,which provides a new solution for integration of Bluetooth and clinic care technology.

18.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-593570

ABSTRACT

Objective To design LCD system based on MSP430 using LCD controller S1D13700. Methods MSP430's control bus adopted the communication mode of MSC-51 singlechips, and was connected with S1D13700 by 8-bit data bus. The address buses were linked by the modes of indirect address and direct address respectively. Results The design was used for displaying cardiac wave and its parameters in cardiac monitor successfully. Conclusion The S1D13700's driver program, accomplished with standard ANSI-C, is gifted with brilliant versatility, and thus can be used in the design of the portable device.

19.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-593567

ABSTRACT

Objective To develop ECG Holter system with SD card as storage medium. Methods Data that used MSP430F449 SCM to acquire 3-channel ECG signal to record SD card through serial peripheral interface were reviewed and analyzed on computer. Results Portable ECG Holter System based on SD card is realized. The using of SD card can enhance storage performance. Conclusion Low-cost, and high-performance solution program is observed.

20.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-588591

ABSTRACT

A system adapted for depot management in hospital based on RFID technology is introduced. With resolution of RFID from PHILIPS and RF transmission from Nordic VLSI Norway, the storage of medical materials and medical equipments can be identified, labeled and statistically controlled accurately and expediently. The system can not only save a mass of work force, but also improve work efficiency.

SELECTION OF CITATIONS
SEARCH DETAIL